Kuraray PVA fiber for Cement, Mortar and Concrete

Fiber type
Diameter
(mm)
Thickness
(dtex)
Cut length
(mm)*
Tensile
Strength
(N/mm2)
Elongation
(%)
Young's
Modulus
(kN/mm2)
Specific Gravity
Primary Applications
RECS7
0.027
7
6
1600
(1.6GPa)
-
39
1.3
Crack control and reinforcement of mortar applications
RECS15
0.04
15
8
1600
(1.6GPa)
7
40
1.3
PVA-ECC and other mortar reinforcement
RSC15 0.04 15 8 1300
(1.3GPa)
7 30 1.3 Crack control at very low dosages
RFS400
0.2
400
18
1000
(1.0GPa)
8
29
1.3
Mortar, concrete
RF4000
0.66
4444
30
900
(0.9GPa)
7
23
1.3
Aggregate above 3/4" (20mm) and shotcrete


RF400
12mm
RF4000
30mm
RECS7
6mm
RECS15
8mm


Note:
1. Different cut lengths are available. Please contact us.
2. RECS and RFS are resin-bundled type.